4 Locations
Cabinets, custom cages, private suites.
Diverse fiber infrastructure.
Specifically optimized for high-density deployment.
Secure storage in all facilities.
Redundant N+1 power and cooling systems.
Unique multi-pod site design.
Redundant diesel generators, N+1 power coguration.
5MW Pacific power service, substantial onsite fuel storage.
Overhead A & B starline bus service.
120V and 208V service.
15A, 20A, & 30A circuits.
N+1 cooling redundancy.
Ultra-efficient indirect evaporative cooling.
Supports high power densities.
Low latency to west coast USA and Asia/Pacific.
24-hour staffing of network operations center.
24/7 escorted on-site entry.
Alarm system with CCTV surveillance throughout the facility.
Biometric finger scanners; access cards.
SSAE 16 Type II / PCI-DSS compliant data center.
Cabinets, custom cages, and private suites solutions.
Low natural disaster area.
Secure storage in all facilities.
Spacious parking for all facilities; convenient to front entrances.
4MW total power; 1.6 MW capacity with ultimate load of 133 Watts/ SF - expandable.
AC + DC centralized power barclay systems; high priority power grid.
Onan diesel generators; 1,500 Kw generator in environmentally protected enclosure.
24kv feed from Duke Energy.
Ultimate load of 124 watts/SF.
300 ton upgradeable to 500 ton cooling capacity.
DX CRAC units with closed glycol loop provide cooling for up to 146 watts/SF.
Expansion available of HVAC plant for higher density installations.
Complete NOC monitoring of environmental systems (CRAC units controlled on floor).
Low latency to the eastern seaboard of the US.
Diverse entry of fiber routes with private dark fiber access to other facilities.
24/7 manned security center.
24/7 interior/exterior camera system monitored on and off site.
Secured building perimeters with no windows.
Biometric finger scanners, badge/pin access.
Man traps with motion activated alarm notification.
Smoke and heat detection at and above ceiling and other critical areas.
Double-Interlock pre-action (Dry Pipe) system over data floor (Total-Pac).
24/7 technical support staff on-site.
Easy access to kitchen/break room.
On-site customer support center available.
Business continuity center.
2 transformers with 3500 kVA capacity with expansion to 10MW.
2 x 2 MW cummins generator backup.
3 x 600 Liebert kVA UPS in 2N+1 configuration.
14 x 125 kVA Liebert PDUs in an A/B configuration.
12 x 30-ton Liebert air-cooled units totaling 360 tons in N+2 configuration.
24/7 secured entrance.
Physical access pre-approved via access permissions defined by the customer.
Government issued photo ID verification.
Documented ingress and egress history.
Card-key access into data center.
Locking cages / suites.
Interior and exterior video surveillance.
Custom security options available.
Perimeter fence with security gate.
Experienced 24/7 facilities management team.
Environment (thermal conditions) monitored 24/7.
All Building Management Systems (BMS) monitored 24/7.
Comprehensive energy metering systems.
SSAE-16 SOC I Type II and SAS 70 Type II compliant.
PCI DSS compliant.
Cabinets, cages, and private Suites solutions.
Systems above 500-year flood plain.
High-efficiency UPS systems support up to 800 KVA A and B.
LED lighting system.
24 hours of on-site fuel storage.
N, N+1, 2N UPSs, PDUs, and RPPs; N+1 redundancy on generators.
Chilled water CRAC and Glycol.
N+1 mechanical systems.
Dual Cisco 6509's with Edge 6500 Cisco Routers with the latest supervisor cards.
Full Bgp on routers with full routing table (1 million routes).
Three or more carriers on ten (10 Gig) fiber paths from One wilshire.
Redudancy on separate fiber lines connected to One Wilshire.
Dual-interlock pre-action dry-pipe sprinkler system with VESDA.
24-hour staffing of network operations center.
Mission-critical controls and monitoring.
Perimeter and interior IP-DVR cameras available.
Key card access and biometric scanning.
Connections available to AMSIX, DE-CIX and SIX.
Bandwidth providers: KCFiber/liNKCity, Wholesale Internet, Zayo, AT&T, UPN, Consolidated, Hurricane Electric.
Dedicated wave and DF available to 1102 Grand, 1100 Walnut and 101 Holmes.
24/7/365 monitored video surveillance.
100% 4K UHD cameras.
Every part of the data center floor can be seen from 2 angles.
Diverse power feeds from diverse substations (Avondale and NKC).
Dedicated substation breakers.
Dedicated power lines direct to NKC substation.
Evergy Ttier 1 customer (same restore priority as Hospitals and 911).
N+1 natural gas generators
Redundant A/B/C/D power available
N+1 HVAC Units
Raised floor design with hot/cold aisles.
Temperature/Humidity/Pressure sensors on every rack.
Autonomous humidity regulation.